Rev. enferm. UERJ ; 30: e64079, jan. -dez. 2022.
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1371649

ABSTRACT

Objetivo: comparar o comportamento glicêmico dos pacientes em pós-operatório de cirurgia cardíaca valvar e de revascularização do miocárdio, submetidos ao mesmo protocolo de controle glicêmico, e avaliar a incidência de hipoglicemia e mortalidade intra-hospitalar dessa população. Método: estudo de coorte, retrospectivo, quantitativo, que avaliou 354 prontuários de cirurgias realizadas em 2016. Resultados: pacientes revascularizados apresentaram maiores médias glicêmicas (149,14±36,03), maior uso de insulina e coeficiente de variação (23,30%). Entretanto, a incidência de hipoglicemia foi maior entre valvares (35,32%), mais acometidos por lesão renal aguda (6,58%), terapia de substituição renal (11,97%) e mortalidade hospitalar (6,58%). Conclusão: evidenciou-se uma população heterogênea com desfechos clínicos que caracterizaram os valvares como mais criticos, devido a maior número de portadores de fibrilaçao atrial, maior tempo de CEC, e maior uso de vasoaminas e corticosteroides. Logo, é necessário conhecer as particularidades de cada população, para gerenciar protocolos específicos de controle glicêmico para diferentes perfis epidemiológicos.


Objective: to compare the glycemic behavior of patients in the postoperative period of valve heart surgery and myocardial revascularization, submitted to the same glycemic control protocol and to assess the incidence of hypoglycemia and mortality and in-hospital mortality in this population. Method: cohort, retrospective, quantitative study that evaluated 354 medical records of surgeries performed in 2016. Results: revascularized patients had higher blood glucose means (149,14±36.03), greater use of insulin and higher coefficient of variation (23.30%). However, the incidence of hypoglycemia was higher (35.32%) valve patients, more affected by acute kidney injury (6.58%), renal replacement therapy (11.97%) and hospital mortality (6.58%). Conclusion: a heterogeneous population with clinical outcomes that characterized the valves as more critical, due to a greater number of patients with atrial fibrillation, longer CEC time, and greater use of vasoamines and corticosteroids. It is necessary to know the particularities of each population, in order to manage specific glycemic control protocols for different epidemiological profiles.


Objetivo: comparar el comportamiento glucémico de pacientes en postoperatorio de cirugía valvular y revascularización miocárdica, sometidos al mismo protocolo de control glicémico y evaluar la incidencia de hipoglucemia y mortalidad hospitalaria en esta población. Método: estudio de cohorte, retrospectivo, cuantitativo que evaluó 354 historias clínicas, entre agosto y octubre de 2020, de cirugías realizadas en 2016. Resultados: pacientes revascularizados presentaron mayores medias de glucemia (149,14±36,03), mayor uso de insulina y mayor coeficiente de variación (23,30%). Aunque, la incidencia de hipoglucemia fue mayor (35,32%) entre las válvulas, que se vieron más afectadas por daño renal agudo (6,58%), terapia de reemplazo renal (11,97%) y mortalidad hospitalaria (6,58%). Conclusión: el estudio mostró una población heterogénea con resultados clínicos que caracterizaron a las válvulas como más críticas, debido a un mayor número de pacientes con fibrilación auricular, mayor tiempo de CEC y mayor uso de vasoaminas y corticoides. Por tanto, es necesario conocer las particularidades de cada población, para gestionar el control glucémico con protocolos específicos para diferentes perfiles epidemiológicos.

2.
Rev. bras. ter. intensiva ; 31(3): 318-325, jul.-set. 2019. tab
Article in Portuguese | LILACS | ID: biblio-1042580

ABSTRACT

RESUMO Objetivo: Validar o instrumento "Lista de Verificação (checklist) para o Gerenciamento do Despertar Diário de Pacientes Críticos". Métodos: Estudo descritivo com abordagem quantitativa para a validação de conteúdo utilizando o método Delphi, para a obtenção de consenso de especialistas que apreciaram o instrumento, por meio de escala tipo Likert. O índice de validade de cada item do instrumento foi calculado para sua validação, tendo como parâmetro mínimo consenso acima de 0,78. Resultados: Foram necessárias três rodadas Delphi, iniciada com 29 e finalizada com 15 especialistas, convidados pessoalmente e via correio eletrônico a participarem do estudo. O instrumento com 15 itens teve 13 deles validados com índice de validade de conteúdo > 0,78. O instrumento manteve seus atributos, sendo reformulados seis itens, sem necessidade de exclusão de algum deles. Os itens validados permitiram avaliar e decidir sobre as dimensões relacionadas ao nível de sedação e agitação, sinais vitais, parâmetros ventilatórios e dor. Pode-se dizer que o instrumento apresentou indicadores psicométricos de validade de conteúdo aceitáveis. Conclusão: O instrumento proposto no estudo apresentou validade de conteúdo na maioria de seus itens e mostra-se como estratégia prática no gerenciamento da interrupção diária da sedação de pacientes críticos.


ABSTRACT Objective: To validate the "Checklist for Managing Critical Patients' Daily Awakening" instrument. Methods: This was a descriptive study that used a quantitative approach for content validation using the Delphi method to obtain the consensus of experts who evaluated the instrument using a Likert scale. The validity index of each item of the instrument was calculated, with a minimum consensus parameter above 0.78. Results: Three Delphi rounds were required, starting with 29 experts and ending with 15 experts who were invited in person and via e-mail to participate in the study. Of the 15 items in the instrument, 13 had a content validity index > 0.78. The instrument maintained its attributes, and six items were reformulated without the need to exclude any of them. The validated items enabled the assessment of and decisions regarding the dimensions related to the level of sedation and agitation, vital signs, ventilatory parameters and pain. The instrument presented psychometric indicators with acceptable content validity. Conclusion: The instrument proposed in the study exhibited content validity for most of its items and emerges as a practical strategy for the management of the daily interruption of sedation of critical patients.


Subject(s)
Humans , Critical Illness , Checklist
3.
Rev. bras. enferm ; 72(3): 609-616, May.-Jun. 2019. tab, graf
Article in English | BDENF, LILACS | ID: biblio-1013566

ABSTRACT

ABSTRACT Objective: To measure the magnitude of the effect of an individualized parameterization protocol for hemodynamic alarms in patients with acute myocardial infarction. Method: Pragmatic clinical trial, open label and single arm, whose intervention was performed through a protocol validated and tested in 32 patients using multiparametric monitors. The heart rate, blood pressure, respiratory rate, oxygen saturation and ST segment-monitoring were measured and classified for clinical consistency one hour before and after the intervention, for 64 hours. Results: The protocol obtained Content Validity Index of 0.92. Of the 460 registered alarms, 261 were considered inconsistent before the intervention and 47 after it. The Relative Risk of inconsistent alarms after the protocol was 0.32 (95% CI 0.23-0.43, p <0.0001). Conclusion: The protocol proved to be a protective factor to the appearance of inconsistent clinical alarms of multiparametric monitors.


RESUMEN Objetivo: Medir la magnitud del efecto de un protocolo de parametrización individualizada de alarmas hemodinámicas en pacientes con infarto agudo de miocardio. Método: Ensayo clínico pragmático, open label y single arm cuya intervención ocurrió por medio de un protocolo validado y testado en 32 pacientes, utilizándose monitores multiparamétricos. Las alarmas de frecuencia cardíaca, presión arterial, frecuencia respiratoria, saturación de oxígeno y segmento ST fueron valorados y clasificados según su consistencia clínica, una hora antes y después de la intervención, durante 64 horas. Resultados: El protocolo obtuvo un índice de Validez de Contenido de 0,92. De las 460 alarmas registradas, 261 fueron consideradas inconsistentes antes de la intervención y 47 después. El Riesgo Relativo de las alarmas incoherentes después del protocolo fue de 0,32 (IC 95% 0.23-0.43, p <0,0001). Conclusión: El protocolo se mostró un factor protector al surgimiento de alarmas clínicas inconsistentes de monitores multiparamétricos.


RESUMO Objetivo: Medir a magnitude do efeito de um protocolo de parametrização individualizada de alarmes hemodinâmicos em pacientes com infarto agudo do miocárdio. Método: Ensaio clínico pragmático, open label e single arm, cuja intervenção ocorreu por meio de um protocolo validado e testado em 32 pacientes usando monitores multiparamétricos. Os alarmes de frequência cardíaca, pressão arterial, frequência respiratória, saturação de oxigênio e segmento ST foram mensurados e classificados quanto à consistência clínica uma hora antes e após a intervenção, durante 64 horas. Resultados: O protocolo obteve Índice de Validade de Conteúdo de 0,92. Dos 460 alarmes registrados, 261 foram considerados inconsistentes antes da intervenção e 47 após. O Risco Relativo de alarmes inconsistentes após o protocolo foi de 0,32 (IC 95% 0.23-0.43, p<0,0001). Conclusão: O protocolo mostrou-se um fator protetor ao surgimento de alarmes clínicos inconsistentes de monitores multiparamétricos.


Subject(s)
Humans , Male , Female , Aged , Monitoring, Physiologic/nursing , Myocardial Infarction/nursing , Blood Pressure/physiology , Electrocardiography/nursing , Electrocardiography/standards , Clinical Alarms , Heart Rate/physiology , Intensive Care Units/organization & administration , Intensive Care Units/statistics & numerical data , Middle Aged , Monitoring, Physiologic/standards
4.
Rev. pesqui. cuid. fundam. (Online) ; 10(4): 1020-1025, out.-dez. 2018. tab, il
Article in English, Portuguese | LILACS, BDENF | ID: biblio-916071

ABSTRACT

Objetivo: Mensurar a variação do duplo-produto nos pacientes com infarto agudo do miocárdio submetidos ao banho de aspersão. Métodos: Pesquisa observacional realizada na Unidade Coronariana de um hospital de referência em cardiologia localizado na cidade do Rio de Janeiro. A amostragem deu-se por conveniência e teve como amostra os banhos de aspersão de pacientes adultos, ambos os sexos, com diagnóstico médico de infarto agudo do miocárdio com supradesnível ou sem supradesnível de segmento ST, e que tivessem indicação de banho de aspersão, fornecida pelo médico e enfermeiro responsáveis. Resultados: Houve aumento do valor médio do duplo-produto em todos os pacientes acompanhados, porém sem significância estatística. Conclusão: A indicação do banho de aspersão nesta amostra foi segura


Objective: To measure the variation of the double product in patients with acute myocardial infarction submitted to spray bath. Methods: Observational study, conducted in the Coronary Care Unit of a referral hospital in cardiology located in the city of Rio de Janeiro. Sampling was given for convenience and was to sample the spray baths adult patients, both sexes, with a diagnosis of AMI with elevation or non-ST segment elevation, and they had spray bath indication provided by the doctor and nurse responsible. Results: There was increase in the average value of the double product in all patients followed, but without statistical significance. Conclusion: The indication of the spray bath in this sample was safe


Objetivo: Medir la variación del doble producto en pacientes con infarto agudo de miocardio sometido a baño de aerosol. Métodos: Estudio observacional, realizado en la Unidad Coronaria de un hospital de referencia en cardiología ubicada en la ciudad de Río de Janeiro. El muestreo se da por conveniencia y era para probar los baños de aspersión pacientes adultos, de ambos sexos, con diagnóstico de IAM con elevación o sin elevación del segmento ST, y que había indicación de baño de aerosol proporcionada por el médico y la enfermera responsable. Resultados: No hubo aumento en el valor medio de la doble producto en todos los pacientes siguió, pero sin significación estadística. Conclusión: La indicación del baño de pulverización en esta muestra era seguro